Density

Alcohol, Volatile acidity and Density – Complete configuration!

Density meter, model ALM-155, Kem
High precision oscillating capillary density meter, for the density analysis in wines and musts on samples “as it is” and for alcohol, after sample distillation..

Density meter, model ALM-155, Kem

High precision oscillating capillary density meter, for the density analysis in wines and musts on samples “as it is” and for alcohol, after sample distillation.
High precision and reliability
The fifth decimal resolution for density and the centesimal one for alcohol, together with Peltier thermostating to ensure the data exactly refers to 20.0 °C, make the instrument suitable to satisfy what is required by official methods.
The illuminated cell, visible from a special window, allows you to view the presence of any bubbles.
Very user-friendly, fast and easy to clean
The analysis starts by simply pressing a button: the instrument will load the sample into the measuring cell via a peristaltic pump & the analytical data will be obtained on average after only two minutes!
For the cleaning at the end of the day, simply suck up water using the peristaltic pump.
Calibration with air and water
The quintessential standard for oscillating capillary density meters is distilled water.
To calibrate the ALM-155, simply suck in bi-distilled water in the cell after selecting the “calibration” option: the instrument will be perfectly aligned in a few minutes.

Portable density meter DA130 N, Kem

For density measurement (based on the oscillating capillary principle) and its related parameters (Alcohol 20 °C, API tables A/B/D, Salinity, H2SO4, Plato, Brix, and others).
Settable concentration tables are available.
The user can define and store 10 temperature coefficients for automatic compensation.

Alcoholometers and mostimeters

M5 – ALCOWEIGHT, hydrostatic balance

System for detection of alcoholic volumetric title and dry extract, and for evaluation of musts in accordance with OIV method and according to Regulations 2870/2000 and 128/2004.
The large Touch-Screen display allows the selection of parameters to be analyzed.
Automatic calibration programmed with internal motor weight.
Possibility of verification and calibration with DKD certified masses
Relative density range from 0.00 to 2.30 g/cm3
Reading precision D = 0.00001
Accuracy: 0.00005
Repeatability: ±0.00005
Temperature compensation: 10-30 °C
Thermocouple: Pt100 1/3 DIN – Sensitivity: 0.01 °C
Accuracy and repeatability: ±0.05 °C
Reading: 0.1 °C
Recommended environment conditions between 10 and 30 °C.

Accessories and spares for M5

(suitable also for the former model Alcoweight II)